2006~2009年汕头市潮阳区二次供水水质监测分析Analysis of Water Quality Monitoring Data from Secondary Water Supply in Chaoyang District from 2006 to 2009
马雪贞
MA Xue-zheng.(Chaoyang District Center for Disease Control and Prevention
摘要(Abstract):
[目的]了解汕头市潮阳区二次供水水质状况,为在区内开展有效的卫生监督提供数据,保证群众饮用水的安全。[方法]2006~2009年6月对潮阳区内的53家二次供水单位的蓄水池每年采检2次,依据GB 17051-1997《二次供水设施卫生规范》、GB/T 5750-2006《生活饮用水标准检验法》和GB 5749-2006《生活饮用水卫生标准》检测细菌总数、大肠菌群、浑浊度、亚硝酸盐等13个指标并进行评价。[结果]2006~2009年共检测326份水样,合格的215份,合格率为65.95%。各年的合格率分别为86.25%、72.62%、57.79%、41.51%,呈逐年下降趋势,差异有统计学意义(P<0.01)。在检测的项目中以余氯、细菌总数、大肠菌群合格率最低,分别为72.70%、74.85%、81.29%。不同时间段的二次供水水样合格率的差异无统计学意义(P>0.05);不同类型单位的二次供水水样合格率差异无统计学意义(P>0.05);市政供水为水源的二次供水水样合格率(72.78%)高于以其他为水源的二次供水的合格率(59.52%),差异有统计学意义(P<0.05)。[结论]潮阳区二次供水水质合格率偏低,须加强卫生监督力度,强化供水单位管理人员专业技术水平,提高二次供水的卫生质量。
[Objective]To understand the status of water quality from secondary water supply in Chaoyang district of Shantou city,to provide data for carrying out effective health supervision and guarantee safe drinking water.[Methods]Water samples collected from 53 secondary ware supply units 2 times each year were tested for total amount of bacteria,coli group,turbidity,nitrite including 13 items based on 《Hygienic Specification for Facilities of Secondary Water Supply》(GB 17051-1997) and 《Standard Examination Methods for Drinking Water》(GB/T 5750-2006),and 《Standard of Drinking Water Quality》(GB 5749-2006)and evaluated.[Results]Of the 326 water samples tested from 2006 to 2009,215 of them were up to standard,accounting for 66.0%.The qualified rate was 86.25%,72.62%,57.79% and 41.51% respectively each year,there was a difference(P<0.01).The qualified rate of residual chlorine(72.7%),colony counts(74.8%) and coli group(81.3%) was the lowest.There was no difference of the qualified rate of the water from secondary water supply collected in different time and units(P>0.05).The qualified rate of water samples collected from municipal secondary water supply was higher(72.8%) than that from other secondary water supply(59.5%),there was a difference(P<0.05).[Conclusion]The qualified rate of the water from secondary water supply was lower in Chaoyang district,health supervision must be strengthened,level of professional technological personnel must be improved,in order to improve the quality of secondary supply water.
关键词(KeyWords):
二次供水;监测
Secondary water supply;Monitoring
基金项目(Foundation):
作者(Author):
马雪贞
MA Xue-zheng.(Chaoyang District Center for Disease Control and Prevention
DOI: 10.16406/j.pmt.issn.1672-9153.2010.03.011
参考文献(References):
- [1]庞天才,林兰,陈怡静.2002~2006年阳江市二次供水水质监测结果分析[J].中国热带医学,2007,7(7):1 259-1 260.
- [2]林海,蒋海青.2003~2007年深圳市盐田区二次供水水质监测结果分析[J].现代预防医学2008,35(15):2 988-2 989.
- [3]韩文霞.安阳市2004~2007年二次供水卫生状况分析[J].公共卫生与预防医学,2008,19(5):78-80.
- [4]孟柯,王秀臣,赵惠玲.一起二次供水污染引起腹泻病爆发的报告[J].首都公共卫生,2008,2(2):82-84.
- [5]杜英林,石峰,杜华堂.2006年聊城市城区二次供水卫生状况调查[J].预防医学论坛,2008,14(12):1 099-1 100.